C-ACT: Applied Chemical Technology

LANL Main Page | Phonebook | Chemistry Division
main page | personnel | publications | posters | key contacts
main page | capabilities | technologies | publications | posters | reference | contacts
main page | capabilities | technologies | posters | contact
main page | technologies | resources | contact | collaborators
main page | applications | capabilities | publications | contacts

Page Name

small logo

Gas Analysis

Main Page | Gas Analysis | Chem. Cert. | Liquid Separation | Compat.

The Material Testing Laboratory (MTL) maintains an extensive and comprehensive gas analysis capability. Highly skilled technical staff operate and maintain dedicated state-of-the-art analytical instrumentation for this purpose. Instrumentation includes bench-top Gas Chromatographs, Quadrapole Mass Spectrometers and Moisture Analyzers. Gas mixture ratios can be determined from 100% down to the 0.1% range. Trace contaminants can be quantitated down to the low ppb level.

Instrumentation

Gas Chromatography

Gas ChromatographyThe MTL utilizes the latest Agilent Technologies® model 6890N gas chromatagraph (shown at right) equipped with TCD, FID and PDD detectors. The Pulsed Discharge Detector (PDD) has a 10x higher sensitivity and response level over conventional GC detectors and is easily capable of determining gas contaminants down in the low ppb levels.

Mass Spectrometers

Mass SpectrometerThe MTL also maintains a dual set of bench-top quadrapole mass spectrometers. The Thermo Onix VG ProLab™ (shown at left) is designed around a triple filter quadrapole with a patented contamination resistant enclosed ion source. This instrument allows the MTL to achieve fast real-time measurements as well as the flexibility to measure virtually any gas at atmospheric pressure in the range of low ppb levels up to 100%.

Spectra MiniLabThe Spectra MiniLab™ (shown at right) offers the MTL the capability of having a backup or "confirming" instrument to the ProLab™ for those analyses requiring the highest of confidence levels. The MiniLab™ offers many of the same features as the ProLab™ and is also capable of determining concentrations of gas mixtures over a wide dynamic range from ppb to percent levels.

Moisture Analyzers

EdgeTech DewPrime III Dew Point HygrometerThe MTL utilizes the EdgeTech DewPrime III™ Dew Point Hygrometer (shown at left). This state-of-the-art micro-processor based, programmable instrument has a wide measurement range (-75 to +100°C) dew point or (0 to 100,000) PPMv. Chilled mirror technology, automatic correction for mirror contaminants and NIST certified calibration ensure the highest levels of precision and accuracy in our data.

Contact: Timothy Ellis


Operated by the University of California for the US Department of Energy | ©2004 UC | Disclaimer/Privacy